What is Cutoff Frequency? — Cutoff Frequency Definition
The cutoff frequency (also called the corner frequency or break frequency) of an electronic filter circuit is the frequency at which the output signal begins to attenuate significantly. More precisely, at the cutoff frequency the ratio of output power to input power drops to 1/2, or the voltage gain (output voltage / input voltage) falls to 1/√2 ≈ 0.707 (−3 dB).
This −3 dB point divides the passband (frequencies that pass through with minimal loss) from the stopband (frequencies that are attenuated). Every filter — low-pass, high-pass, band-pass, or band-stop — has at least one cutoff frequency that defines its behavior.
What is a Filter Circuit?
A filter circuit is an electronic network that passes signals of certain frequencies while blocking or attenuating signals at other frequencies. The two simplest passive filter topologies use only resistors plus either a capacitor or an inductor:
- RC filter — resistor (R) and capacitor (C) in series; the output is taken across C (low-pass) or across R (high-pass).
- RL filter — resistor (R) and inductor (L) in series; the output is taken across L (high-pass) or across R (low-pass).
Both RC and RL circuits are first-order filters: their frequency-response rolls off at −20 dB/decade beyond the cutoff point.
Formula for Cutoff Frequency of an RC Filter Circuit
For a first-order RC filter the cutoff frequency is:
where:
- fc — cutoff (corner) frequency in hertz (Hz)
- R — resistance in ohms (Ω)
- C — capacitance in farads (F)
The corresponding angular frequency and time constant are:
- ωc = 2π fc = 1 / (R × C) — angular frequency (rad/s)
- τ = R × C — time constant (s); fc = 1 / (2π τ)
Formula for Cutoff Frequency of an RL Filter Circuit
For a first-order RL filter the cutoff frequency is:
where:
- fc — cutoff frequency in hertz (Hz)
- R — resistance in ohms (Ω)
- L — inductance in henries (H)
The angular frequency and time constant for an RL filter:
- ωc = R / L — angular frequency (rad/s)
- τ = L / R — time constant (s)
How to Calculate Cutoff Frequency
RC Filter Example (American / Metric System)
Given: R = 10 kΩ = 10,000 Ω, C = 100 nF = 100 × 10⁻⁹ F = 10⁻⁷ F
Step 1 — Time constant:
τ = R × C = 10,000 × 10⁻⁷ = 10⁻³ s = 1 ms
Step 2 — Cutoff frequency:
fc = 1 / (2π × τ) = 1 / (2π × 0.001) ≈ 159.15 Hz
RL Filter Example
Given: R = 1 kΩ = 1,000 Ω, L = 100 mH = 0.1 H
Step 1 — Time constant:
τ = L / R = 0.1 / 1,000 = 10⁻⁴ s = 0.1 ms
Step 2 — Cutoff frequency:
fc = R / (2π × L) = 1,000 / (2π × 0.1) ≈ 1,591.5 Hz ≈ 1.59 kHz
How to Use the Cutoff Frequency Calculator
- Select the filter type: RC (resistor-capacitor) or RL (resistor-inductor).
- Enter the resistance and choose its unit: Ω, kΩ, or MΩ.
- For an RC filter — enter the capacitance and choose F, μF, nF, or pF.
- For an RL filter — enter the inductance and choose H, mH, or μH.
- Click Calculate. The calculator returns the cutoff frequency (Hz / kHz / MHz / GHz), angular frequency ω (rad/s), and time constant τ.
Unit Systems Supported
The calculator works identically with both American and metric (SI) conventions because electrical engineering uses the same SI units worldwide. Resistance in ohms (Ω), capacitance in farads (F), and inductance in henries (H) are universal. Practical sub-units such as kΩ, MΩ, μF, nF, pF, mH, and μH are supported via the drop-down selectors.
FAQs
- What does −3 dB mean at the cutoff frequency?
- At fc the output power is halved (3 dB less than the input). In voltage terms, the output is 1/√2 ≈ 70.7% of the input. This is the internationally accepted definition of the cutoff (half-power) point.
- Is the cutoff frequency the same for low-pass and high-pass RC filters?
- Yes. The formula fc = 1/(2πRC) applies to both configurations. Only the component across which you measure the output changes (capacitor → low-pass; resistor → high-pass).
- What units should I use?
- Use consistent SI base units in the formulas: ohms for R, farads for C, henries for L. This calculator handles the unit conversion automatically when you select kΩ, μF, nF, mH, etc.
- What is the difference between cutoff frequency and resonant frequency?
- Cutoff frequency is a property of first-order RC or RL filters (single reactive element). Resonant frequency applies to second-order LC or RLC circuits where inductive and capacitive reactances cancel. The resonant frequency formula is fr = 1/(2π√(LC)).
- Can I use this calculator for audio crossover design?
- Yes. A first-order RC filter with fc in the audio range (20 Hz – 20 kHz) is the building block for simple speaker crossovers. Enter your desired crossover frequency and a convenient capacitor value to find the required resistor (or vice versa).
- What is the −20 dB/decade roll-off?
- Beyond the cutoff frequency, a first-order (single-pole) filter attenuates the output by 20 dB for every tenfold increase in frequency. For example, at 10 × fc the gain is −20 dB (10% of the passband value); at 100 × fc it is −40 dB (1%).