What is Vapor Pressure Deficit (VPD)?
Vapor pressure deficit (VPD) is the difference between the amount of moisture in the air and the amount of moisture the air could hold at saturation. It is typically expressed in pressure units — kilopascals (kPa) in metric or PSI in imperial (American) units. VPD is a key metric in horticulture because it correlates directly with how quickly plants transpire (lose water through leaf stomata).
This calculator was developed with reference to the horticultural research of Dr. Erik Runkle (Michigan State University) and David Llewellyn (University of Guelph).
What Does VPD Mean for Plants?
Plants regulate water loss through the opening and closing of tiny pores called stomata. VPD drives the rate of this water movement:
- Low VPD (< 0.4 kPa / 0.058 PSI): The air is very humid. Plants transpire slowly. Risk of mold, mildew, and fungal diseases increases. Beneficial during early propagation of cuttings and seedlings.
- Ideal VPD for vegetative growth (0.8 – 1.2 kPa / 0.116 – 0.174 PSI): Healthy stomatal activity, strong gas exchange, and efficient photosynthesis. Best for leafy growth.
- Ideal VPD for flowering/fruiting (1.2 – 1.6 kPa / 0.174 – 0.232 PSI): Encourages robust transpiration and nutrient uptake during flowering and fruit development.
- High VPD (> 1.6 kPa / 0.232 PSI): Plants experience water stress. At very high levels (> 2.0 kPa), stomata close to conserve water, reducing both transpiration and CO₂ uptake, ultimately slowing growth.
Relative Humidity vs. Vapor Pressure
A common question is: why not just use relative humidity (RH)? RH tells you the percentage of moisture in the air relative to what the air can hold at a given temperature. The problem is that warm air holds much more moisture than cold air, so the same RH value represents very different amounts of "drying power" at different temperatures.
Example: 60% RH at 35 °C (95 °F) feels much drier than 60% RH at 18 °C (64 °F). VPD, unlike RH, directly measures the pressure difference driving evaporation — making it a far more reliable indicator of transpiration rate.
How to Calculate Vapor Pressure Deficit
The VPD formula uses the Magnus equation to find saturation vapor pressure (SVP):
SVP(T) = 0.6108 × exp(17.27 × T / (T + 237.3)) [T in °C, SVP in kPa]
Then:
AVP = SVP(T_air) × RH / 100 (Actual Vapor Pressure)
VPD = SVP(T_air) − AVP (Vapor Pressure Deficit)
For imperial units, convert temperatures to °C for calculation, then multiply kPa by 0.145038 to get PSI.
Leaf VPD (Canopy Temperature Method)
Because the leaf surface is often warmer than the surrounding air, the more accurate leaf VPD uses the canopy (leaf) temperature:
SVP_leaf = 0.6108 × exp(17.27 × T_canopy / (T_canopy + 237.3))
Leaf VPD = SVP_leaf − AVP_air
Using leaf VPD instead of air VPD gives a more precise picture of the drying stress on the leaf surface. Canopy temperature is typically 1–3 °C cooler than air temperature in well-transpiring plants.
Calculate VPD Using Dew Point
If you know the dew point temperature (the temperature at which air becomes saturated), you can derive AVP directly:
AVP = SVP(T_dew)
VPD = SVP(T_air) − AVP
Calculate VPD Using Wet-Bulb Temperature
A sling psychrometer gives the wet-bulb temperature. Using the psychrometric equation:
AVP = SVP(T_wet) − A × (T_dry − T_wet) × P
where A = 0.000799 (Assman psychrometer), P = atmospheric pressure in kPa
Example Calculation
Metric example: Air temperature = 25 °C, Relative humidity = 60%
- SVP(25) = 0.6108 × exp(17.27 × 25 / (25 + 237.3)) ≈ 3.1671 kPa
- AVP = 3.1671 × 60 / 100 ≈ 1.9003 kPa
- VPD = 3.1671 − 1.9003 ≈ 1.267 kPa → Ideal for flowering
Imperial example: Air temperature = 77 °F, Relative humidity = 60%
- Convert: 77 °F = 25 °C → SVP ≈ 3.1671 kPa = 0.4593 PSI
- AVP ≈ 1.9003 kPa = 0.2756 PSI
- VPD ≈ 1.267 kPa = 0.1837 PSI
VPD Reference Chart
| VPD Zone | kPa | PSI | Plant Response |
|---|---|---|---|
| Very Low | < 0.4 | < 0.058 | Slow transpiration; disease risk |
| Low — Propagation | 0.4 – 0.8 | 0.058 – 0.116 | Ideal for seedlings and clones |
| Ideal — Vegetative | 0.8 – 1.2 | 0.116 – 0.174 | Strong leaf growth |
| Ideal — Flowering | 1.2 – 1.6 | 0.174 – 0.232 | Optimal fruiting/flowering |
| High — Stress | 1.6 – 2.0 | 0.232 – 0.290 | Water stress possible |
| Very High | > 2.0 | > 0.290 | Stomata close; growth slows |