Wet Bulb Temperature Calculator — Calculate Wet-Bulb Temperature from Humidity

Calculate wet-bulb temperature using the Stull formula from dry-bulb temperature and relative humidity. Supports metric (°C) and imperial (°F) unit systems.

0 calculations

Calculation Parameters

°C

Valid range: −20°C to 50°C

%

Valid range: 5% to 100%

Enter Parameters

Fill in the form on the left and click "Calculate"

What is the Wet-Bulb Temperature?

The wet-bulb temperature is the lowest temperature that air can reach through evaporative cooling only. It is measured using a thermometer wrapped in water-soaked fabric (a wet wick) that is ventilated. As water evaporates from the wick, it cools the thermometer below the ambient (dry-bulb) air temperature. When humidity is 100%, no evaporation occurs and wet-bulb temperature equals dry-bulb temperature.

How to Calculate the Wet-Bulb Temperature?

Our calculator uses the Stull formula (2011), which provides excellent accuracy for relative humidities between 5% and 99% and temperatures between −20°C and 50°C:

Tw = T·arctan(0.151977·√(RH+8.313659)) + 0.00391838·√(RH³)·arctan(0.023101·RH) − arctan(RH−1.676331) + arctan(T+RH) − 4.686035

Where T is the dry-bulb temperature in °C and RH is the relative humidity in %.

Both metric (°C) and imperial (°F) unit systems are supported. Simply select your preferred unit system, enter the air temperature and relative humidity, and get the wet-bulb temperature instantly.

Wet-Bulb Calculator Applications

  • Construction — Materials react differently to humidity. Wet-bulb temperature guides climate-specific building design.
  • Snowmaking — Snow guns require low temperatures. As humidity drops, wet-bulb temperature rises, affecting snow production.
  • Meteorology — Forecasters use wet-bulb temperature to predict rain, snow, sleet, and freezing rain.
  • Agriculture — Helps assess crop stress and irrigation needs during heat events.
  • Industrial hygiene — Workplace safety standards often reference wet-bulb temperature for heat stress management.

Wet-Bulb Globe Temperature (WBGT)

The Wet-Bulb Globe Temperature (WBGT) is a composite index used by the military, athletes, and industrial hygienists to assess heat stress risk. Unlike the simple wet-bulb temperature, WBGT also accounts for wind speed, radiant heat (sunlight), and air temperature:

WBGT (outdoors) = 0.7·Tw + 0.2·Tg + 0.1·Td

Where Tw = wet-bulb temperature, Tg = globe thermometer temperature (radiant heat), Td = dry-bulb temperature.

Why Does Wet-Bulb Temperature Matter for Human Health?

Our bodies cool themselves through sweat evaporation. In humid conditions, sweat evaporates slower, reducing our ability to cool down. When wet-bulb temperature reaches 35°C (95°F), even a healthy person at rest cannot maintain a stable core temperature — this is considered the physiological limit of human survivability.

FAQs

What is the difference between dry-bulb and wet-bulb temperature?
Dry-bulb temperature is the standard air temperature. Wet-bulb temperature is always equal to or lower than dry-bulb, and reflects the cooling effect of evaporation.
Can wet-bulb temperature exceed dry-bulb temperature?
No. Wet-bulb temperature is always ≤ dry-bulb temperature. They are equal only when relative humidity is 100%.
What is a dangerous wet-bulb temperature?
A wet-bulb temperature above 28°C is dangerous for outdoor physical activity. Above 35°C is considered fatal for extended exposure.
Does the Stull formula work for all conditions?
The Stull formula is accurate for RH between 5%–99% and temperatures between −20°C and 50°C. Outside these ranges, use a psychrometric chart.