Category

Wire Gauge Calculator — AWG & SWG Diameter, Area & Resistance

Find the diameter, cross-sectional area, and resistance per unit length of any wire gauge. Supports both the American Wire Gauge (AWG) and Standard Wire Gauge (SWG) systems, with copper, aluminum, silver, and gold conductors. Results in metric (mm, mm²) and American (inches, kcmil) units.

0 calculations

Calculation Parameters

Results are shown in both metric (mm, mm²) and American (inch, kcmil) units

Formula Reference

d(mm) = 0.127 × 92^((36−n)/39)
A = π/4 × d²
R/L = ρ / A

Select a Wire Gauge

Choose the gauge standard, gauge number and material, then click Calculate

Wire Gauge Calculator

The wire gauge calculator lets you know the diameter and cross-sectional area of your chosen wire, as well as the electrical resistance per unit length. This is all very useful if you are wiring up speakers to your home theater system and were looking for a speaker wire gauge calculator.

Use this wire gauge size calculator instead of wading through tedious wire gauge charts. It supports both the American Wire Gauge (AWG) standard and the Standard Wire Gauge (SWG) system.

The American Wire Gauge (AWG) standard

American Wire Gauge is a logarithmically stepped wire gauge system used mainly in North America since 1857. It applies to solid, round, nonferrous electrical wire. For increasing AWG numbers, the diameter and cross-sectional area of the wire get smaller.

The scale is defined at two points. Number 36 AWG wire has a diameter of 0.005 inches, while 0000 (4/0) AWG wire has a diameter of 0.46 inches. The ratio of these two diameters is 1:92, and there are 39 steps between them. The formula for the diameter of any AWG number n is:

diameter (in) = 0.005 inch × 92(36 − n)/39
diameter (mm) = 0.127 mm × 92(36 − n)/39

For AWG gauge numbers 0, 00, 000, and 0000, a negative number must be used for n. So for gauge 1/0 use n = 0; for 2/0 use n = −1; for 3/0 use n = −2; and for 4/0 use n = −3.

As a rule of thumb, if you decrease the AWG number by six, the diameter of the wire doubles. The cross-sectional area in terms of the AWG number is found using the area of a circle:

area = π/4 × diameter²

The Standard Wire Gauge (SWG)

This wire gauge calculator also supports the British Standard Wire Gauge (SWG), also known as the Imperial Wire Gauge or British Standard Gauge. SWG is not so popular these days, but it is still used to define the thickness of guitar strings, as well as some types of electrical wiring.

SWG is built on the base unit of the mil, which is 0.001 inch (a thousandth of an inch). The gauge number defines the diameter of the wire and ranges from the largest, number 7/0 at 500 mil (0.5 inch), to the smallest, number 50 at 1 mil (0.001 inch). Each step of the scale reduces the weight per unit length by approximately 20 percent. Unlike AWG, SWG diameters come from a fixed standard table rather than a single formula.

Electrical resistance per unit length

Once the cross-sectional area is known, the calculator computes the DC resistance per unit length using Pouillet's law:

R / L = ρ / A

Where:

  • R / L — resistance per unit length (Ω/km or Ω/1000 ft);
  • ρ — the resistivity of the conductor material (Ω·m); and
  • A — the cross-sectional area of the wire (m²).

The calculator supports the following materials (resistivity at 20 °C):

  • Copper — 1.68 × 10⁻⁸ Ω·m (the most common conductor)
  • Aluminum — 2.65 × 10⁻⁸ Ω·m
  • Silver — 1.59 × 10⁻⁸ Ω·m (the best conductor)
  • Gold — 2.44 × 10⁻⁸ Ω·m

How to use the wire gauge calculator

  1. Choose your unit system — metric (mm, mm²) or American (inches, in², kcmil).
  2. Select the gauge standard — AWG or SWG.
  3. Pick the gauge number from the list.
  4. Choose the conductor material to get the resistance per unit length.

The calculator instantly returns the diameter, cross-sectional area, and resistance per unit length.

Worked example — 12 gauge wire (AWG)

For AWG 12, n = 12, so the diameter is 0.127 mm × 92(36 − 12)/39 ≈ 2.053 mm (0.0808 in). The cross-sectional area is π/4 × (2.053 mm)² ≈ 3.31 mm². With copper (ρ = 1.68 × 10⁻⁸ Ω·m), the resistance is about 5.1 Ω/km (1.56 Ω/1000 ft) — a typical value for household wiring.

FAQs

Does a higher gauge number mean a thicker wire?
No — it is the opposite. For both AWG and SWG, a higher gauge number means a thinner wire with a smaller cross-sectional area and a higher resistance per unit length.

What is the difference between AWG and SWG?
AWG (American Wire Gauge) is defined by a logarithmic formula and is used mainly in North America. SWG (Standard Wire Gauge) is a British system defined by a fixed table of diameters. The same gauge number gives slightly different diameters in each system.

Why does the resistance depend on the material?
Resistance per unit length is proportional to the material's resistivity. Silver and copper have low resistivity (low resistance), while aluminum and gold have higher resistivity for the same wire size.

Calculation History

Loading...